Abstract
The integration of semi-continuous pan coaters in continuous manufacturing lines has increased due to recent advancements in continuous manufacturing. Although there is a profound knowledge of semi-continuous pan coating of tablets with a non-functional coating, no studies have addressed functional coating.
Therefore, a screening study was performed on a semi-continuous pan coater whereby the influence of different coating parameters (weight gain, inlet air temperature, spray rate and inlet airflow rate) was investigated on coating efficiency, coating film layer, inter-tablet coating variability and dissolution profile of tablets with a controlled release profile. None of the coating parameters significantly influenced the inter-tablet coating variability and low variability (<1% RSD on mass, thickness, diameter) was obtained.
At the lowest weight gain level (4%), the inlet air temperature influenced the film formation mechanism whereby a controlled release profile was only obtained at high inlet air temperature (complete particle coalescence).
Continue reading here
Materials
The tablet cores consisted of dense acetaminophen (APAP) (Mallinckrodt, Hazelwood, USA), microcrystalline cellulose (Avicel PH102; FMC Health and Nutrition, Cork, Ireland), spray dried lactose monohydrate (Supertab 11SD; DFE Pharma, Goch, Germany) and magnesium stearate (Ligamed MF-2-V; Peter Greven, Bad Münstereifel, Germany). The coating dispersion was formulated as a mixture of two controlled release polymers, Eudragit RS 30 D and RL 30 D (in a ratio 9:1) (Evonik Operations, Darmstadt.
Phaedra Denduyver, Quinten Speleers, Leslie Van Eeckhout, Fabian Penson, Chris Vervaet, Valérie Vanhoorne, Semi-continuous pan coating of controlled release tablets: A screening study, Journal of Drug Delivery Science and Technology, Volume 127, Part 3, 2027, 109054, ISSN 1773-2247, https://doi.org/10.1016/j.jddst.2026.109054.
Are you looking for excipients in commercial quantities?